Why a field survey belongs in diligence
Operating data shows what a plant produced. A full-plant thermal survey shows its physical condition today: strings that aren't producing, modules degrading faster than the warranty assumes and connections close to failure. That changes repair reserves, warranty claims and sometimes price.
Scope
- Full-plant radiometric thermal and RGB survey to IEC TS 62446-3
- Anomaly register by block, string and module, with severity classes
- Estimated energy and revenue at risk by finding class
- Battery-storage exterior survey where the plant includes storage
- Complete raw data package with capture log for your independent engineer
How we work with deal teams
- Engagement. Engaged by the buyer, the lender or the independent engineer, with confidentiality terms in the services agreement.
- Access. Site access arranged through the seller's O&M team; we follow their safety rules.
- Delivery. Findings delivered to the named recipients only, with the raw data, so the independent engineer can verify any result.
Portfolios
For multi-site transactions we can screen the portfolio first and focus full surveys where the data suggests the most risk, then apply the same method and severity classes to every site so results compare cleanly.
Questions
Are you independent of the seller?
Yes. We are engaged by the buyer, lender or their engineer, and we don't sell repairs, equipment or O&M services.
Who receives the data?
Only the recipients named in the engagement. Retention follows the services agreement.